MON069 Atomic Absorption Spectrophotometer

Functions  Details
Wavelength range 190 – 900nm
Spectral bandwidth Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
Accuracy of the wavelength ±0.15nm
Receptivity of the wavelength ≤0.04nm
Base line stability ≤0.002A/30min (Cu)
Characteristic viscosity 0.02μg/ml/1% (Cu)
Checking limit 0.004μg/ml (Cu)
Preciseness 0.5%
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp stand Eight lamps
Dbackground correction ability When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Size and weight 700mm×550mm×450mm  75Kg
Power source 220V±22V  AC
Flame system
Acetylene air burner 100mm
Nitrous oxide acetylene flame head 50mm
Ignition dynamic baseline drift ≤0.006A/30min
(Cu) Characteristic viscosity ≤0.025μg/ml/1%
Related standard deviation of the accuracy ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety system Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.
Graphite furnace
The highest temperature 3000ºC
The largest temperature rising speed ≥2000ºC/S
Characteristic quantity Cd≤0.5×10-12g  Cu≤0.5×10-11g
Accuracy Cu≤3%  Cd≤3%
Size and weight 550mm×450mm×300mm  65Kg
Safety system Over current protection
Low air pressure alarm / protection
Low cooling water flow alarm/protection
Power source and power 220V±22V  AC   7000W

Description

Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)
Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.
Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp
Position adjusting: the best height of the flame burner and can automatically set the front and rear positions
Fully automated wavelength scanning and peak searching
Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout
Deuterium lamp and self-absorption background regulation
Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with in the form of EXCEL and the testing method and the result can be randomly called
Measuring method: flame absorption method and emission method
Result printing: parameter printing, data result printing and diagram printing

Reviews

There are no reviews yet.

Be the first to review “MON069 Atomic Absorption Spectrophotometer”