MON526 Monophasic Defi-Monitor GD-9000D

Features:

Main unit: Portable
Dimensions: L320xW205xH410
Weight: 9.5kg

Specifications:

1. DEFIBRILLATOR.
1.1 Defibrillator type: Manual,Synchronized, Asynchronized,
1.2 Energy accuracy: ∠+1%
1.3 Energy selection: 0,3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of50)
1.4 Charging time: Maximum 10 seconds to 360 Joules
1.5 StandardAdult/Pediatric Paddles Reusable externaladult paddles (pediatric paddles integrated)
2. PowerRequirements.
2.1 AC Power supply: 100V~240V,50Hz/60 Hz
2.2 Vehicle Voltage (Option):DC 12V
3. InternalBattery Backup
3.1 Battery type:Rechargeable lead-acid battery (12V 2.0Ah X2)
3.2 Charging time: Time-Minimumof 4 hours for full charging
3.3 Batterycharging: During AC Power Supply operation of the device.
3.4 Charging /Low Battery Indication: Red LED
3.5 BatteryCapacity: 100% of the battery will provide 120-min monitoring; and 30discharges at 360 joules.
4. Display
4.1 LCD Dimensions: 7-inch
4.2 Type: Highresolution true-color graphic
4.3 Resolution: 480X234
5. ECG
5.1 ECG lead: Ⅰ, Ⅱ, Ⅲ,AVR, AVL, AVF, V1~V6
5.2 S-T segmentanalysis: -2.0~2.0mv
5.3 Arrhythmia analysis:yes
5.4 Protection: Withstand 4000vAc/50Hz voltage in isolation and work against electrosurgical knifeand defibrillation
6. Respiration
6.1Measurement method:Thoracic impedance
7. Standardparameter & configuration
ECG/RESP/DEFIBRILLATOR

Description

Features:

Main unit: Portable
Dimensions: L320xW205xH410
Weight: 9.5kg

Specifications:

1. DEFIBRILLATOR.
1.1 Defibrillator type: Manual,Synchronized, Asynchronized,
1.2 Energy accuracy: ∠+1%
1.3 Energy selection: 0,3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of50)
1.4 Charging time: Maximum 10 seconds to 360 Joules
1.5 StandardAdult/Pediatric Paddles Reusable externaladult paddles (pediatric paddles integrated)
2. PowerRequirements.
2.1 AC Power supply: 100V~240V,50Hz/60 Hz
2.2 Vehicle Voltage (Option):DC 12V
3. InternalBattery Backup
3.1 Battery type:Rechargeable lead-acid battery (12V 2.0Ah X2)
3.2 Charging time: Time-Minimumof 4 hours for full charging
3.3 Batterycharging: During AC Power Supply operation of the device.
3.4 Charging /Low Battery Indication: Red LED
3.5 BatteryCapacity: 100% of the battery will provide 120-min monitoring; and 30discharges at 360 joules.
4. Display
4.1 LCD Dimensions: 7-inch
4.2 Type: Highresolution true-color graphic
4.3 Resolution: 480X234
5. ECG
5.1 ECG lead: Ⅰ, Ⅱ, Ⅲ,AVR, AVL, AVF, V1~V6
5.2 S-T segmentanalysis: -2.0~2.0mv
5.3 Arrhythmia analysis:yes
5.4 Protection: Withstand 4000vAc/50Hz voltage in isolation and work against electrosurgical knifeand defibrillation
6. Respiration
6.1Measurement method:Thoracic impedance
7. Standardparameter & configuration
ECG/RESP/DEFIBRILLATOR

Reviews

There are no reviews yet.

Be the first to review “MON526 Monophasic Defi-Monitor GD-9000D”